Normal attributes
hwloc objects have many generic attributes in the hwloc_obj structure, for instance their logical_index or os_index (see Should I use logical or physical/OS indexes? and how?), depth or name .
The kind of object is first described by the obj->type generic attribute (an integer). OS devices also have a specific obj->attr->osdev.type integer for distinguishing between NICs, GPUs, etc. Objects may also have an optional obj->subtype pointing to a better description string. For instance subtype is useful to say what Group objects are actually made of (e.g. Book for Linux S/390 books). It may also specify that a Block OS device is a Disk, or that a CoProcessor OS device is a CUDA device. This subtype is displayed by lstopo either in place or after the main obj->type attribute. NUMA nodes that correspond GPU memory may also have GPUMemory as subtype.
Each object also contains an attr field that, if non NULL, points to a union hwloc_obj_attr_u of type-specific attribute structures. For instance, a L2Cache object obj contains cache-specific information in obj->attr->cache , such as its size and associativity, cache type. See hwloc_obj_attr_u for details.
Custom string infos
Aside os these generic attribute fields, hwloc annotates many objects with string attributes that are made of a key and a value. Each object contains a list of such pairs that may be consulted manually (looking at the object infos array field) or using the hwloc_obj_get_info_by_name(). The user may additionally add new key-value pairs to any object using hwloc_obj_add_info() or the hwloc-annotate program.
Here is a non-exhaustive list of attributes that may be automatically added by hwloc. Note that these attributes heavily depend on the ability of the operating system to report them. Many of them will therefore be missing on some OS.
Operating System Information
These info attributes are attached to the root object (Machine).
- OSName, OSRelease, OSVersion, HostName, Architecture
- The operating system name, release, version, the hostname and the architecture name, as reported by the Unix
uname command.
- LinuxCgroup
- The name the Linux control group where the calling process is placed.
- WindowsBuildEnvironment
- Either MinGW or Cygwin when one of these environments was used during build.
hwloc Information
Unless specified, these info attributes are attached to the root object (Machine).
- Backend (topology root, or specific object added by that backend)
- The name of the hwloc backend/component that filled the topology. If several components were combined, multiple Backend keys may exist, with different values, for instance
x86 and Linux in the root object and CUDA in CUDA OS device objects.
- SyntheticDescription
- The description string that was given to hwloc to build this synthetic topology.
- hwlocVersion
- The version number of the hwloc library that was used to generate the topology. If the topology was loaded from XML, this is not the hwloc version that loaded it, but rather the first hwloc instance that exported the topology to XML earlier.
- ProcessName
- The name of the process that contains the hwloc library that was used to generate the topology. If the topology was from XML, this is not the hwloc process that loaded it, but rather the first process that exported the topology to XML earlier.
CPU Information
These info attributes are attached to Package objects, or to the root object (Machine) if package locality information is missing.
- CPUModel
- The processor model name.
- CPUVendor, CPUModelNumber, CPUFamilyNumber, CPUStepping
- The processor vendor name, model number, family number, and stepping number. Currently available for x86 and Xeon Phi processors on most systems, and for ia64 processors on Linux (except CPUStepping).
- CPURevision
- A POWER/PowerPC-specific general processor revision number, currently only available on Linux.
- CPUType
- A Solaris-specific general processor type name, such as "i86pc".
OS Device Information
These info attributes are attached to OS device objects specified in parentheses.
- Vendor, Model, Revision, SerialNumber, Size, SectorSize (Block OS devices)
- The vendor and model names, revision, serial number, size (in kB) and SectorSize (in bytes).
- LinuxDeviceID (Block OS devices)
- The major/minor device number such as 8:0 of Linux device.
- GPUVendor, GPUModel (GPU or Co-Processor OS devices)
- The vendor and model names of the GPU device.
- OpenCLDeviceType, OpenCLPlatformIndex,
- OpenCLPlatformName, OpenCLPlatformDeviceIndex (OpenCL OS devices)
- The type of OpenCL device, the OpenCL platform index and name, and the index of the device within the platform.
- OpenCLComputeUnits, OpenCLGlobalMemorySize (OpenCL OS devices)
- The number of compute units and global memory size (in kB) of an OpenCL device.
- LevelZeroVendor, LevelZeroModel, LevelZeroBrand,
- LevelZeroSerialNumber, LevelZeroBoardNumber (LevelZero OS devices)
- The name of the vendor, device mode, brand of a Level Zero device, and its serial and board numbers.
- LevelZeroDriverIndex, LevelZeroDriverDeviceIndex (LevelZero OS devices)
- The index of the Level Zero driver within the list of drivers, and the index of the device within the list of devices managed by this driver.
- LevelZeroCQGroups, LevelZeroCQGroup2 (LevelZero OS devices)
- The number of completion queue groups, and the description of the third group (as
N*0xX where N is the number of queues in the group, and 0xX is the hexadecimal bitmask of ze_command_queue_group_property_flag_t listing properties of those queues).
- AMDUUID, AMDSerial (RSMI GPU OS devices)
- The UUID and serial number of AMD GPUs.
- XGMIHiveID (RSMI GPU OS devices)
- The ID of the group of GPUs (Hive) interconnected by XGMI links
- XGMIPeers (RSMI GPU OS devices)
- The list of RSMI OS devices that are directly connected to the current device through XGMI links. They are given as a space-separated list of object names, for instance rsmi2 rsmi3.
- NVIDIAUUID, NVIDIASerial (NVML GPU OS devices)
- The UUID and serial number of NVIDIA GPUs.
- CUDAMultiProcessors, CUDACoresPerMP,
- CUDAGlobalMemorySize, CUDAL2CacheSize, CUDASharedMemorySizePerMP (CUDA OS devices)
- The number of shared multiprocessors, the number of cores per multiprocessor, the global memory size, the (global) L2 cache size, and size of the shared memory in each multiprocessor of a CUDA device. Sizes are in kB.
- VectorEngineModel, VectorEngineSerialNumber (VectorEngine OS devices)
- The model and serial number of a VectorEngine device.
- VectorEngineCores, VectorEngineMemorySize, VectorEngineLLCSize,
- VectorEngineL2Size, VectorEngineL1dSize, VectorEngineL1iSize (VectorEngine OS devices)
- The number of cores, memory size, and the sizes of the (global) last level cache and of L2, L1d and L1i caches of a VectorEngine device. Sizes are in kB.
- VectorEngineNUMAPartitioned (VectorEngine OS devices)
- If this attribute exists, the VectorEngine device is configured in partitioned mode with multiple NUMA nodes.
- Address, Port (Network interface OS devices)
- The MAC address and the port number of a software network interface, such as
eth4 on Linux.
- NodeGUID, SysImageGUID, Port1State, Port2LID, Port2LMC, Port3GID1 (OpenFabrics OS devices)
- The node GUID and GUID mask, the state of a port #1 (value is 4 when active), the LID and LID mask count of port #2, and GID #1 of port #3.
Other Object-specific Information
These info attributes are attached to objects specified in parentheses.
- DAXDevice (NUMA Nodes)
- The name of the Linux DAX device that was used to expose a non-volatile memory region as a volatile NUMA node.
- PCIBusID (GPUMemory NUMA Nodes)
- The PCI bus ID of the GPU whose memory is exposed in this NUMA node.
- Inclusive (Caches)
- The inclusiveness of a cache (1 if inclusive, 0 otherwise). Currently only available on x86 processors.
- SolarisProcessorGroup (Group)
- The Solaris kstat processor group name that was used to build this Group object.
- PCIVendor, PCIDevice (PCI devices and bridges)
- The vendor and device names of the PCI device.
- PCISlot (PCI devices or Bridges)
- The name/number of the physical slot where the device is plugged. If the physical device contains PCI bridges above the actual PCI device, the attribute may be attached to the highest bridge (i.e. the first object that actually appears below the physical slot).
- Vendor, AssetTag, PartNumber, DeviceLocation, BankLocation (MemoryModule Misc objects)
- Information about memory modules (DIMMs) extracted from SMBIOS.
User-Given Information
Here is a non-exhaustive list of user-provided info attributes that have a special meaning:
- lstopoStyle
- Enforces the style of an object (background and text colors) in the graphical output of lstopo. See CUSTOM COLORS in the lstopo(1) manpage for details.
|
|